Lorven 6000

Fully Automated CLIA Analyzer

LORVEN 6000 Fully Automated CLIA Analyzer

• More Compact                                     •MoreAccurate

• Multiple combination, single assay module repetition measurement.
• Quantitative detection of autoimmune items, allergens, cytokines, thrombus and routine items.
• Throughput: Up to 200 T/H.
• Reagent positions: 20 (It can be expanded to 55 for allergens).
• Sample positions: 50

Technical Specifications:

General information:

Throughput: Up to 200 T/H.
Measurement Principle: Alkaline phosphatase chemiluminescence method.
First result: 15 mins.

• Cuvette Loading and Waste Collection:

Cuvette: Disposable plastic cuvette.
Cuvette Loading: ≥800, continuous loading, real-time reserve monitoring.

• Sample Assembly:

Sample Feeder: Continuous Loading.
Sample Positions: 50, STAT available.
Types of Sample Tube: Micro sample cup, blood collection tube, plastic test tube.
Sample Probe: Nanopolished probe, carry-over prevention, cross-contamination prevention.
Sampling System: Automatic duplicate measurement, liquid level detection, horizontal and vertical collision prtection, clot detectuion.
Sample Volume: 5~100 μL, with increment of 1 μ.
Sample Dilution: Automatic dilution with 1:2~1:2500.

Reagent Assembly:

Reagent Positions: 20, it can be expanded to 55 for allergens.
Cooling System: 2-8 °C, 24 hours on-board refrigeration.
Reagent Scanning: Built-in barcode scanner, automatic barcode recognition.
Reagent Probe: Nanopolished probe, carry-over prevention, cross-contamination prevention.
Reagent loading: Random access, continuous loading.
Reagent Volume: 20~150 μ, with increment of 1 μ.

Substrate System:

Substrate Loading: Capable of continuous loading during test.
Substrate Heating: Substrate pre-heating.

Software System:

Bidirectional LIS connection, independent reporting system.

Magnetic Separation Unit:

Separation Assembly: Dual washing system, 8-phase magnetic separation.
Temperature: Accuracy: 37≠0.3°C.

Mesurement and Reaction System:

Detection Mode: Photon counting.
Single Detector: Photomultiplier (PMT).
PMT Calibration: LED reference module.
Incubation Positions: 101.
Temperature: Constant temperature control.
Mixing Unit: Intelligent adjustment of mixing speed, non-contact vortexer mixing.

Working Conditions:

Voltage Input: 220V~50Hz.
Input Power: 1500VA.
External Dimension: (L*W*H): 995mm×670mm×620mm.
Net Weight: 150kg.

Fully Automated Clia Analyzers. 

Our diagnostic platform offers a comprehensive range of high-quality tests with fast turnaround times, supporting precise assessment of autoimmune conditions, inflammation, thrombosis risk, allergies, and routine health parameters.

Test Menu:
Autoimmune Panel
Cytokines Panel
Thrombus Panel
Allergen Panel
Routine Tests