Fully Automated CLIA Analyzer
LORVEN 6000 Fully Automated CLIA Analyzer
• More Compact •MoreAccurate
• Multiple combination, single assay module repetition measurement.
• Quantitative detection of autoimmune items, allergens, cytokines, thrombus and routine items.
• Throughput: Up to 200 T/H.
• Reagent positions: 20 (It can be expanded to 55 for allergens).
• Sample positions: 50
Technical Specifications:
• General information:
Throughput: Up to 200 T/H.
Measurement Principle: Alkaline phosphatase chemiluminescence method.
First result: 15 mins.
• Cuvette Loading and Waste Collection:
Cuvette: Disposable plastic cuvette.
Cuvette Loading: ≥800, continuous loading, real-time reserve monitoring.
• Sample Assembly:
Sample Feeder: Continuous Loading.
Sample Positions: 50, STAT available.
Types of Sample Tube: Micro sample cup, blood collection tube, plastic test tube.
Sample Probe: Nanopolished probe, carry-over prevention, cross-contamination prevention.
Sampling System: Automatic duplicate measurement, liquid level detection, horizontal and vertical collision prtection, clot detectuion.
Sample Volume: 5~100 μL, with increment of 1 μ.
Sample Dilution: Automatic dilution with 1:2~1:2500.
Reagent Assembly:
Reagent Positions: 20, it can be expanded to 55 for allergens.
Cooling System: 2-8 °C, 24 hours on-board refrigeration.
Reagent Scanning: Built-in barcode scanner, automatic barcode recognition.
Reagent Probe: Nanopolished probe, carry-over prevention, cross-contamination prevention.
Reagent loading: Random access, continuous loading.
Reagent Volume: 20~150 μ, with increment of 1 μ.
Substrate System:
Substrate Loading: Capable of continuous loading during test.
Substrate Heating: Substrate pre-heating.
Software System:
Bidirectional LIS connection, independent reporting system.
Magnetic Separation Unit:
Separation Assembly: Dual washing system, 8-phase magnetic separation.
Temperature: Accuracy: 37≠0.3°C.
Mesurement and Reaction System:
Detection Mode: Photon counting.
Single Detector: Photomultiplier (PMT).
PMT Calibration: LED reference module.
Incubation Positions: 101.
Temperature: Constant temperature control.
Mixing Unit: Intelligent adjustment of mixing speed, non-contact vortexer mixing.
Working Conditions:
Voltage Input: 220V~50Hz.
Input Power: 1500VA.
External Dimension: (L*W*H): 995mm×670mm×620mm.
Net Weight: 150kg.
Fully Automated Clia Analyzers.
Our diagnostic platform offers a comprehensive range of high-quality tests with fast turnaround times, supporting precise assessment of autoimmune conditions, inflammation, thrombosis risk, allergies, and routine health parameters.
Test Menu:
• Autoimmune Panel
• Cytokines Panel
• Thrombus Panel
• Allergen Panel
• Routine Tests